Very smooth and even silica surface

Performance, quality, delivery, technical support and cost effectiveness

Venusil HPLC columns are manufactured from the highest purity spherical silica particles on the market. The outstanding properties of the HPLC phases are the results of an innovative surface modification and unique bonding processes.

Venusil phases

Phase Functional group Particle, um Pore, A pH range Use
Venusil ASB
ASB-C1 C1 5 150 1 - 7.5 This stationary phase is end-capped with polar groups and thus has the highest polarity among Venusil family columns. It can be used to replace Waters Atlantis, Zorbax SB, and other brand AQ columns.
ASB-C3 C3 5 150 1 - 7.5  
ASB-C8 C8 3, 5, 10 150 0.8 - 7.5  
ASB-C18 C18 3, 5 150 0.8 - 7.5 Extremely stable at pH 1. Specially designed for the separation of small polar compounds.
ASB-PHENYL PHENYL 5 150 1 - 7.5  
Venusil XBP
XBP-C1 C1 5 100 1.5 - 10.0 Venusil XBP columns are bonded to the maximum density to have the highest hydrophobicity (the lowest polarity), the lowest interaction of analytes with silanol, high stability at high pH's and the broadest pH range.
XBP-C4 C4 5 100 1.5 - 10.0
XBP-C8 C8 3, 5, 10 100 1.5 - 10.0
XBP-C18 C18 3, 5, 10 100 1.5 - 10.0
XBP-Phenyl Phenyl 5 100 1.5 - 10.0
XBP-NH2 NH2 5, 10 100 1.5 - 10.0
XBP-CN CN 5, 10 100 1.5 - 10.0
XBP-COOH R-COOH 5 100 1.5 - 10.0
XBP-DIOL DIOL 5 100 1.5 - 10.0
XBP-HILIC HILIC 3, 5, 10 100 1.5 - 10.0
Venusil XBP(L)
XBP(L)-C8 C8 5 150 1.5 - 7.5 These are very hydrophobic phases. They have a relatively low surface area which allows compounds to have shorter retention times. These columns are excellent alternatives to Hypersil BDS-C8 and BDS-C18.
XBP(L)-C18 C18 5 150 1.5 - 7.5
Misc.
AQ-C18 C18 3, 5 100 1.5 - 9.0 This phase is more polar than XBP-C18 and less polar than ASB-C18. It is a true C18 column compatible with 100% aqueous mobile phase.
SCX SCX 5 150, 300 1.5 - 7.5  
SAX SAX 5 150, 300 1.5 - 7.5  
PAH C18 5 200 1.5 - 7.5 This column is recommended for the separation of PAHs and steric isomers of aromatic compounds.
PFP PentaFluoroPhenyl 5 120 1.5 - 7.5 This phase will increase retention and resolution, and is particularly suited for the separation of halogenated species as well as compounds containing hydroxyl, carboxyl, nitro or other polar groups. The additional mechanisms of the PFP phase, such as steric selectivity of the analyte species and dipole interactions, offer alternative selectivity.
HLP (High Load Phase) alkyl +embedded amide 5 100 1.5 - 7.5 This phase can be used to replace Waters Symmetry Shield RP18 and Agilent Bonus RP.